 * \file MS_health_server_api.h
 *
 * \brief This file defines the Mesh Health Model Application Interface
 * - includes Data Structures and Methods for both Server and Client.
 */

/*
 * Copyright (C) 2017. Mindtree Ltd.
 * All rights reserved.
 */

#ifndef _H_MS_HEALTH_SERVER_API_
#define _H_MS_HEALTH_SERVER_API_


/* --------------------------------------------- Header File Inclusion */
#include "MS_access_api.h"


/* --------------------------------------------- Global Definitions */
/**
 *  \defgroup health_fault_values Fault Values
 *  \{
 *  This section lists the Fault Values defined for Health Model.
 */

/** Health Model - Fault Values */
/** No Fault */
#define MS_HEALTH_FAULT_NO_FAULT                                0x00
/** Battery Low Warning */
#define MS_HEALTH_FAULT_BATTERY_LOW_WARNING                     0x01
/** Battery Low Error */
#define MS_HEALTH_FAULT_BATTERY_LOW_ERROR                       0x02
/** Supply Voltage Too Low Warning */
#define MS_HEALTH_FAULT_SUPPLY_VOLTAGE_TOO_LOW_WARNING          0x03
/** Supply Voltage Too Low Error */
#define MS_HEALTH_FAULT_SUPPLY_VOLTAGE_TOO_LOW_ERROR            0x04
/** Supply Voltage Too High Warning */
#define MS_HEALTH_FAULT_SUPPLY_VOLTAGE_TOO_HIGH_WARNING         0x05
/** Supply Voltage Too High Error */
#define MS_HEALTH_FAULT_SUPPLY_VOLTAGE_TOO_HIGH_ERROR           0x06
/** Power Supply Interrupted Warning */
#define MS_HEALTH_FAULT_POWER_SUPPLY_INTERRUPTED_WARNING        0x07
/** Power Supply Interrupted Error */
#define MS_HEALTH_FAULT_POWER_SUPPLY_INTERRUPTED_ERROR          0x08
/** No Load Warning */
#define MS_HEALTH_FAULT_NO_LOAD_WARNING                         0x09
/** No Load Error */
#define MS_HEALTH_FAULT_NO_LOAD_ERROR                           0x0A
/** Overload Warning */
#define MS_HEALTH_FAULT_OVERLOAD_WARNING                        0x0B
/** Overload Error */
#define MS_HEALTH_FAULT_OVERLOAD_ERROR                          0x0C
/** Overheat Warning */
#define MS_HEALTH_FAULT_OVERHEAT_WARNING                        0x0D
/** Overheat Error */
#define MS_HEALTH_FAULT_OVERHEAT_ERROR                          0x0E
/** Condensation Warning */
#define MS_HEALTH_FAULT_CONDENSATION_WARNING                    0x0F
/** Condensation Error */
#define MS_HEALTH_FAULT_CONDENSATION_ERROR                      0x10
/** Vibration Warning */
#define MS_HEALTH_FAULT_VIBRATION_WARNING                       0x11
/** Vibration Error */
#define MS_HEALTH_FAULT_VIBRATION_ERROR                         0x12
/** Configuration Warning */
#define MS_HEALTH_FAULT_CONFIGURATION_WARNING                   0x13
/** Configuration Error */
#define MS_HEALTH_FAULT_CONFIGURATION_ERROR                     0x14
/** Element Not Calibrated Warning */
#define MS_HEALTH_FAULT_ELEMENT_NOT_CALIBRATED_WARNING          0x15
/** Element Not Calibrated Error */
#define MS_HEALTH_FAULT_ELEMENT_NOT_CALIBRATED_ERROR            0x16
/** Memory Warning */
#define MS_HEALTH_FAULT_MEMORY_WARNING                          0x17
/** Memory Error */
#define MS_HEALTH_FAULT_MEMORY_ERROR                            0x18
/** Self-Test Warning */
#define MS_HEALTH_FAULT_SELF_TEST_WARNING                       0x19
/** Self-Test Error */
#define MS_HEALTH_FAULT_SELF_TEST_ERROR                         0x1A
/** Input Too Low Warning */
#define MS_HEALTH_FAULT_INPUT_TOO_LOW_WARNING                   0x1B
/** Input Too Low Error */
#define MS_HEALTH_FAULT_INPUT_TOO_LOW_ERROR                     0x1C
/** Input Too High Warning */
#define MS_HEALTH_FAULT_INPUT_TOO_HIGH_WARNING                  0x1D
/** Input Too High Error */
#define MS_HEALTH_FAULT_INPUT_TOO_HIGH_ERROR                    0x1E
/** Input No Change Warning */
#define MS_HEALTH_FAULT_INPUT_NO_CHANGE_WARNING                 0x1F
/** Input No Change Error */
#define MS_HEALTH_FAULT_INPUT_NO_CHANGE_ERROR                   0x20
/** Actuator Blocked Warning */
#define MS_HEALTH_FAULT_ACTUATOR_BLOCKED_WARNING                0x21
/** Actuator Blocked Error */
#define MS_HEALTH_FAULT_ACTUATOR_BLOCKED_ERROR                  0x22
/** Housing Opened Warning */
#define MS_HEALTH_FAULT_HOUSING_OPENED_WARNING                  0x23
/** Housing Opened Error */
#define MS_HEALTH_FAULT_HOUSING_OPENED_ERROR                    0x24
/** Tamper Warning */
#define MS_HEALTH_FAULT_TAMPER_WARNING                          0x25
/** Tamper Error */
#define MS_HEALTH_FAULT_TAMPER_ERROR                            0x26
/** Device Moved Warning */
#define MS_HEALTH_FAULT_DEVICE_MOVED_WARNING                    0x27
/** Device Moved Error */
#define MS_HEALTH_FAULT_DEVICE_MOVED_ERROR                      0x28
/** Device Dropped Warning */
#define MS_HEALTH_FAULT_DEVICE_DROPPED_WARNING                  0x29
/** Device Dropped Error */
#define MS_HEALTH_FAULT_DEVICE_DROPPED_ERROR                    0x2A
/** Overflow Warning */
#define MS_HEALTH_FAULT_OVERFLOW_WARNING                        0x2B
/** Overflow Error */
#define MS_HEALTH_FAULT_OVERFLOW_ERROR                          0x2C
/** Empty Warning */
#define MS_HEALTH_FAULT_EMPTY_WARNING                           0x2D
/** Empty Error */
#define MS_HEALTH_FAULT_EMPTY_ERROR                             0x2E
/** Internal Bus Warning */
#define MS_HEALTH_FAULT_INTERNAL_BUS_WARNING                    0x2F
/** Internal Bus Error */
#define MS_HEALTH_FAULT_INTERNAL_BUS_ERROR                      0x30
/** Mechanism Jammed Warning */
#define MS_HEALTH_FAULT_MECHANISM_JAMMED_WARNING                0x31
/** Mechanism Jammed Error*/
#define MS_HEALTH_FAULT_MECHANISM_JAMMED_ERROR                  0x32

/* 0x33 - 0x7F: Reserved for Future Use */
/* 0x80 - 0xFF: Vendor Specific Warning / Error */

/** \} */

/**
*  \defgroup health_server_events Health Server Events
*  \{
*  This section lists the Application Events defined for Health Server Model.
*/

/** Attention Start */
#define MS_HEALTH_SERVER_ATTENTION_START                       0x01

/** Attention Restart */
#define MS_HEALTH_SERVER_ATTENTION_RESTART                     0x02

/** Attention Stop */
#define MS_HEALTH_SERVER_ATTENTION_STOP                        0x03

/** \} */


/* --------------------------------------------- Data Types/ Structures */
/**
 * \brief Health Server application Asynchronous Notification Callback.
 *
 * \par Description
 * Health Server calls the registered callback to indicate events occurred to the
 * application.
 *
 * \param handle        Model Handle.
 * \param event_type    Health Server Event type.
 * \param event_param   Parameter associated with the event if any or NULL.
 * \param param_len     Size of the event parameter data. 0 if event param is NULL.
 */
typedef API_RESULT (* MS_HEALTH_SERVER_CB)
        (
            MS_ACCESS_MODEL_HANDLE * handle,
            UINT8                    event_type,
            UINT8                  * event_param,
            UINT16                   param_len
        ) DECL_REENTRANT;


/**
 * Health Server Self Test Function.
 */
/* TODO: Add context of the Health Server, so that associated current/registered fault can be updated */
typedef void (* MS_HEALTH_SERVER_SELF_TEST_FN)(UINT8 test_id, UINT16 company_id);

/**
 * Health Server Self Test Funtion Structure.
 */
typedef struct _MS_HEALTH_SERVER_SELF_TEST
{
    /** Test ID */
    UINT8                           test_id;

    /** Self Test Function */
    MS_HEALTH_SERVER_SELF_TEST_FN    self_test_fn;

}MS_HEALTH_SERVER_SELF_TEST;


/* --------------------------------------------- Function */
/**
 *  \brief API to initialize Health Server model
 *
 *  \par Description
 *  This is to initialize Health Server model and to register with Acess layer.
 *
 *  \param [in] element_handle
 *              Element identifier to be associated with the model instance.
 *
 *  \param [in, out] model_handle
 *                   Model identifier associated with the model instance on successful initialization.
 *                   After power cycle of an already provisioned node, the model handle will have
 *                   valid value and the same will be reused for registration.
 *
 *  \param [in]      company_id
 *                   Company Identifier
 *
 *  \param [in]      self_tests
 *                   List of Self Tests that can be run.
 *
 *  \param [in]      num_self_tests
 *                   Number of Self Tests in the list.
 *
 *  \param [in] appl_cb    Application Callback to be used by the Health Server.
 *
 *  \return API_SUCCESS or an error code indicating reason for failure
 */
API_RESULT MS_health_server_init
           (
               /* IN */    MS_ACCESS_ELEMENT_HANDLE     element_handle,
               /* INOUT */ MS_ACCESS_MODEL_HANDLE     * model_handle,
               /* IN */    UINT16                       company_id,
               /* IN */    MS_HEALTH_SERVER_SELF_TEST * self_tests,
               /* IN */    UINT32                       num_self_tests,
               /* IN */    MS_HEALTH_SERVER_CB          appl_cb
           );

/**
 *  \brief API to report self-test fault
 *
 *  \par Description
 *  This is to report fault observed during self-test procedure.
 *
 *  \param [in] model_handle
 *              Model Handle identifying the Health Server model instance.
 *
 *  \param [in]      test_id
 *                   Identifier of the self-test
 *
 *  \param [in]      company_id
 *                   Company Identifier
 *
 *  \param [in]      fault_code
 *                   Fault value indicating the error.
 *
 *  \return API_SUCCESS or an error code indicating reason for failure
 */
API_RESULT MS_health_server_report_fault
           (
               /* IN */ MS_ACCESS_MODEL_HANDLE     * model_handle,
               /* IN */ UINT8                        test_id,
               /* IN */ UINT16                       company_id,
               /* IN */ UINT8                        fault_code
           );

/**
 * \cond ignore_this Ignore this fundtion while generating doxygen document
 */

API_RESULT MS_health_server_publish_current_status
           (
               UCHAR    * status,
               UINT16     length
           );
/**
 * \endcond
 */

#endif /*_H_MS_HEALTH_SERVER_API_ */